Environment (Air) Training

Home → Trainings → Environment (Air) Training

Air Testing and Monitoring is the process of measuring and analysing the quality of air in a specific area to assess the levels of pollutants and ensure that air quality standards are met. It involves using various tools and technologies to detect the presence of harmful substances, such as Particulate Matter (PM), Nitrogen Dioxide (NO2), Carbon Monoxide (CO), Sulphur Dioxide (SO2), Ozone (O3), Ammonia (NH3) and Volatile Organic Compounds (VOCs), Metals etc.  Air testing and monitoring plays a crucial role in public health, environmental protection, and regulatory compliance.

FARE Labs, having an accredited Air Testing and Monitoring Laboratory recognised by the MOEF&CC is equipped with advanced air testing and monitoring technologies, including both fixed station monitoring networks and portable devices offers Training & Certification Program on Air Quality Testing and Monitoring.This training course aims to equip participants with essential knowledge and practical skills in the techniques required for air testing & monitoring. It may be worth mentioning that the training program offered by FARE Labs is one of the best training courses in Gurugram for environmental air quality testing.

 FARE Labs also offers training on testing the quality of industrial and medical gases.

Objectives

  1. Provide a comprehensive understanding of Air Pollution Monitoring & Gases
  2. Equip participants with practical skills for operating and maintaining of Air & Gases analysis.
  3. Discuss method Verification and sample preparation techniques for air pollution monitoring.
  4. Environmental air sampling and analysis training
  5. Familiarize trainees with data analysis, interpretation, and troubleshooting.
  6. Familiarize trainees with air quality testing techniques

What is to learn?

1. Introduction to Analysis of Air & Gas Testing Laboratory

  • Ambient Air: Particulate Matter (PM2.5), Particulate Matter (PM10), Nitrogen Dioxide, Sulphur Dioxide, Ozone, Ammonia, Carbon Monoxide Lead, Nickel, Arsenic, Benzene, Benzo (a) pyrene.
  • Indoor Air: Particulate Matter, Sulphur Dioxide, Nitrogen Dioxide, Ozone, Ammonia, Formaldehyde, Corrosion Rate, Carbon monoxide, Carbon Dioxide, Metals, VOCs, Relative Humidity, Temperature, Air Movement, Ventilation Rate, Light Intensity, Microbiological Analysis.
  • Stack Emission: Particulate Matter (PM), Sulphur Dioxide, Nitrogen Dioxide, Carbon Monoxide, Carbon Dioxide, Oxygen, Velocity, Temperature, Volumetric Flow Rate.
  • Noise Monitoring: Ambient Air, Workzone Noise, DG Noise, Noise Dose
  • Meteorological Monitoring: Wind Direction, Wind Velocity, Temperature, Relative Humidity, Pressure, Solar Radiation.
  • Dioxin & Furan Sampling & Monitoring
  • Compressed Air: Particle Count, Moisture, Oil Mist, Carbon Monoxide, Oxygen, Hydrocarbon, Dew Point.
  • Medical Oxygen: Oxygen, Carbon Monoxide, Carbon Dioxide.
  • Biogas: Methane, Oxygen, Carbon Dioxide, Hydrogen Sulphide, Calorific Value, Moisture

2. Instrumentation and Setup

  • Detailed discussion of Spectrophotometer Components: a light source, monochromator, cuvettes and detectors
  • Detailed discussion of CO Analyser: Non-dispersive infrared (NDIR) sensors
  • Detailed discussion E-bam Sampler: Filter Paper, Beta Radiation Source, Data Logger.

3. Method Development

  • Selecting appropriate analytical methods & Standard for determination for different analytes.
  • Calibration techniques: standard curves and internal standards
  • Determination of Limit of Quantification (LOQ) & Limit of Detection (LOD)

4. Applications of Equipment Using For Air & Gases Analysis

Training will be provided on selected parameters from the list below:

  • Spectrophotometer: Sulphur Dioxide, Nitrogen Dioxide, Ozone, Ammonia, Hydrogen Sulphide, Carbon Disulphide
  • CO Analyser: Carbon Monoxide
  • E-bam Sampler: Particulate Matter10 & Particulate Matter2.5

1. Hands-On Training

  • Instrument setup and calibration for sample analysis
  • Preparation and analysis of more than 500 samples for various matrices
  • Running LC-MS/MS methods: step-by-step guidance

2. Data Analysis and Interpretation

  • Understanding mass spectra and chromatograms
  • Quantification methods and calibration curve creation
  • Software tools for data processing and reporting

3. Troubleshooting Common Issues

  • Identifying and resolving common problems (e.g., baseline noise, peak tailing)
  • Strategies for maintaining instrument performance
  • Preventive maintenance tips
  1. Adherence to Safety Protocols: Strictly follow all laboratory safety guidelines and protocols to prevent accidents and ensure the well-being of all participants.
  2. Active Participation: Engage actively in all training sessions, discussions, and practical exercises. Complete all assigned tasks and projects on time.
  3. Respect for Equipment and Facilities: Handle all laboratory equipment and materials with care. Report any damages or malfunctions to the instructor immediately.
  4. Collaboration and Teamwork: Work collaboratively with fellow participants, sharing knowledge and supporting each other’s learning.
  5. Integrity and Accuracy: Maintain a high standard of integrity in all testing procedures and documentation. Ensure that all results are accurate and reliable.

Commitment to the Program: Participants must demonstrate a commitment to the training program by attending all scheduled sessions, completing all assignments, and actively participating in practical exercises. A signed commitment agreement may be required before the start of the program.

Health and Safety Compliance: Participants must comply with health and safety regulations, including wearing appropriate personal protective equipment (PPE) and adhering to all safety protocols. A medical clearance or proof of immunizations may be required for certain training programs.

Designation: Air Trainee

Section: Training

Qualification:  Ph. D./ M. Tech./ M. Sc./ B. Tech./ B. Sc.

Fees:  As Per Industry Standards

Experience:  Freshers / Professionals

Employment Type:  Short Term / Long Term

Location:  Gurugram, Haryana

 

Note:

Limited Spots Available! Don’t Miss This Opportunity to Advance Your Analytical Skills!

For any further inquiries or additional information, please reach out. We look forward to supporting your journey in analytical excellence!

FARE Labs – Empowering the Future of Analytical Science

CONTACT US FOR SERVICES
Please enable JavaScript in your browser to complete this form.

Get in Touch for Our Services

Please enable JavaScript in your browser to complete this form.