Mechanical Metrology Calibration

HomeServicesCalibration & Research DivisionMechanical Metrology Calibration

Mechanical Metrology:


At Fare Labs, Mechanical metrology comprises of calibration in different disciplines: Weight, Volume, Weighing Scale and Balance, Density and Viscosity, Pressure Indicating Devices, Pressure Balance or Dead Weight Tester, Hardness Machine, Rubber Hardness Tester (Durometer), Torque Generating Devices, Speed and Acceleration, Acoustics, Mobile Force Measuring System and UTM ,Tension Creep and Torsion Testing Machine.


We are serving industries in the following sectors: Laboratory, Medical, Pharmaceutical, Aerospace, Defence, Automotive, Manufacturing, Energy and Utilities, Electronics, Equipment Manufacturer, Food & Beverage, Instrument Suppliers / Dealers..

MASS & VOLUME

In the mass & volume section, different weighing balances and weights are calibrated along with volumetric measuring instruments. We have all classes of weights like E1, E2, M class and also F class ranging from 1mg to 1kg. We also have weighing balances such as micro & semi-micro balances in the range of 1μg to 1000kg to measure weights accurately. We also have micropipettes and all types of glassware for volumes in the range of 1μl to 500ml. We provide large volume storage tank calibration also up to 6500kL.

PRESSURE

Devices such as Pressure switches, Vacuum Gauges, Digital pressure gauges, Pressure transmitters, Transducers, Magnehelic gauges, Differential gauges, Controllers, Relief valves, BP Apparatus & Pressure sensors in the range of -1 bar to 1200 bar are calibrated in this section.

One of the unique capabilities that we possess is the calibration of Ford Cup, the calibration for which is not easily available. We perform Ford Cup calibration in the range of 10cst to 1200cst. Along with that, Hydrometers and viscometers are calibrated in this section. Density Hydrometers ranging from 0.600g/ml to 1.950 g/ml and Viscometer Calibration from 0.001mm2/s2 to 100mm2/s2 is performed in this section.

Discipline Name of the Instrument Parameters to be calibrated Range Standard Instruments available
Mass – Volume – Balance Weighing Balance (Micro / Semi-Micro / Digital / Analytical / Platform) Repeatability, Linearity, Eccentricity, Hysteresis up to 1000 kg E1 / E2 / F1 class weights traceable to NPL / Weightronics / Weigh India
Mass – Volume – Balance Weights E1 / E2 / F1 / F2 / M1 / M2 class
Mass – Volume – Balance Micro pipette / Auto Pipette Volume 1 µl to 10 ml
Mass – Volume – Balance Glassware Volume 0.2 ml to 500 ml
Mass – Volume – Balance Storage Tank (by
Electro-Optical
distance ranging)
Tank with Dia.
Of>5m)
As
per OIML 71 & ISO
7507-5: 2005
20 kl to 6500 kl Total Station
(Resolution Linear
Measurement= 1
mm, Horizontal and
Vertical Angle=2”
Arc resolution)
Density Density Hydrometers/ Specific Gravity Hydrometers / Lactometers / Baume Hydrometer / Alcoholmeter / Butryometer Density of Fluids 0.600 g/ml to 1.950
g/ml
Density Hydrometer traceable to NPL
Viscosity Glass Capillary Viscometers Viscosity Constant 0.001 mm2/s2 to 100 mm2/s2 Viscometer tube traceable to Cannan Fenske
Viscosity Kinematic Viscosity
of Newtonian Liquids
1 mm2/s to 70000 mm2/s
Viscosity Flow Cup /Viscosity Cup / Ford Cup Viscosity Constant 10 mm2/s to 1200
mm2/s
Viscosity Oil traceable to Cannan
Pressure Pneumatic Pressure – Gauge / Transducer / Transmitter / Switch  up to 200 bar Digital Pressure & Vacuum Gauge (Fluke)
Pressure Pneumatic Vacuum – Gauge / Transducer / Transmitter / Switch upto -0.95 bar
Pressure Hydraulic Pressure – Gauge / Transducer / Transmitter / Switch up to 1200 bar Digital Pressure Gauge (Fluke)

Hydraulic DWT (Fluke)

Pressure Dead Weight Tester ( hydraulic)   5 to 1200 bar Hydraulic DWT (Fluke)

 

Pressure Low Pressure – Magnehellic / Laminar Air Flow / Manometer 50 mbar, 1000 mbar Low-Pressure Calibrator( Fluke)
Speed – Acceleration Tachometer / Stroboscope / Tachometer Calibrator / RPM source 6 rpm to 100000 rpm SANSEL Tachometer Calibrator & Fluke Tachometer
ACOUSTICS Sound Level Meter 94 & 114 dB at 1 kHz Sound Level Calibrator traceable to NPL
Torque Torque Wrench / Torque Screw Driver Torque 0.1 Nm to 3000 Nm Sushma Torque Calibrator
Force TTM / CTM / UTM Tension
Compression
5 N to 500 kN
1 kN to 3000 kN
Sushma Load Cell
Hardness Rubber Hardness Tester ( Shore A/D) Rubber Hardness 10 to 100 Shore Rubber Hardness Tester Calibrator
Hardness Hardness Testing Machine ( Rockwell / Brinell / Micro Vickers/ Vickers )  Hardness HRA

HRC

HRBW

HV

Standard Hardness Test Block
Mobile Force Measuring System Push pull gauge Force 0.1   N to 10 N

100 N to 1000 N

Using Newtonian Weights and Frame Fixture
Mechanical Testing Clean Room Validation / LAF / BSC / Pass Box / HVAC Validation AirFlow, Particle Count, Filter Integrity, Air Visualization, Pressure Balancing Anemometer, Particle Counter, Photometer, Aerso

Fluid flow metrology is the science of measuring the rate of fluid movement. It Involves using various techniques and instruments to quantify the amount of fluid, either liquid or gas, that passes through a specific point over a given time period. This field is crucial in various industries for quality control, process optimization, and cost management. 

Flow meters, used to measure the flow rate of liquids and gases, are calibrated to ensure accurate monitoring in applications such as water treatment, oil and gas, and process control.

In this section, we calibrate anemometers and rotameters or fluid flow meters. Fluid flow meters are used in many applications where we need to measure the flow rate of a stream of gas like, natural gas, boiler efficiency, burner control, gas mixing & blending etc. All these applications make the calibration of fluid flow meters an important part, as any kind of errors might lead to unwanted outcomes.

Discipline
Name of the Instrument
Parameters to be calibrated
Range
Standard Instruments available
FLUID FLOW MEASURING DEVICES
Rotameter
Air Flow rate
1 mlpm to 300 lpm
Laminar Flow Element
FLUID FLOW MEASURING DEVICES
Anemometer
Air Velocity
0.6 m/s to 10 m/s
Anemometer
FLUID FLOW MEASURING DEVICES
RDS / HVS
Comparison Method, USPEAIO2.1:
0.6 m3/min to 1.5 m3/min
Using Top Loading Calibrator
FLUID FLOW MEASURING DEVICES
Water Flow Meter
Comparison Method
5 m3/h to 1080 m3/h
Using Ultrasonic Flow Mete
  • Advanced Infrastructure: We utilize cuttingedge equipment and precision standards to ensure bestinclass measurement and calibration.
  • Expert Team: Our skilled and trained professionals understand your needs and deliver results you can trust.
  • Compliance & Traceability: All calibrations adhere to international standards and NABL traceable norms for absolute reliability.
  • Quality You Can Depend On: Minimize downtime, reduce waste, and maintain the highest quality across your products and processes.
CONTACT US FOR SERVICES

Get in Touch for Our Services