Particle Size Analysis Training

Home → Trainings → Particle Size Analysis Training

TRAINING ON PARTICLE SIZE ANALYSIS

Particle size analysis is used to characterise the size distribution of particles in a given sample. Particle size analysis can be applied to solid materials, suspensions, emulsions and even aerosols. Particle size analysis is a very important test and is used for quality control in many different industries. In just about every industry where milling or grinding is used, particle size is a critical factor in determining the efficiency of manufacturing processes and performance of the final product. Some industries and product types where particle sizing is used includes Pharmaceuticals, Building materials, Paints and coatings, Food and beverages.

There are many different methods employed to measure particle size.  Laser diffraction is a widely used, rapid, and non-destructive method for determining particle size distributions across a broad range (typically 0.01–3500 µm).  The range of laser diffraction-based particle size analysers set the standard for delivering rapid, accurate particle size distributions for both wet and dry dispersions. 

FARE Labs offers Particle Size Analysis Training Courses using advanced measurement techniques such as laser diffraction method-based particle size analyser.   We offer online training on particle size analysis as well as offline training.  This powerful technique offers high throughput with high accuracy, high-speed measurements (<1 minute) with both wet and dry dispersion options and user-friendly software. 

Objectives

  • Provide a thorough understanding of principles and instrumentation.
  • Train the trainee and improve their practical skills for operating and maintaining PSA systems.
  • Discuss method development and sample preparation techniques.
  • Familiarize attendees with data analysis, interpretation, and troubleshooting.

What is to learn?

1. Introduction of PSA

  • Basic principle of PSA
  • Instrument operation method
  • Sample preparation method
  • Data analysis and interpretation

 

2. Methods for PSA

  • ISO 13320, Laser diffraction method
  • USP 429, Laser diffraction method

 

3. Method Development

  • New method development procedure
  • Method validation for PSA
  • Instrument calibration

 

4. Application of PSA

  • Pharmaceuticals
  • Cosmetics
  • Building materials
  • Food samples
  • Chemicals
  • Generator oils
  • Paints and emulsions
  • Waste water

1. Hands-On Training

  • Instrument initialization, stabilization and calibration for sample analysis
  • Preparation and analysis of samples for various matrices
  • Instrument operation: step-by-step guidance

 

2. Data Analysis and Interpretation

  • Understanding Laser diffraction method and working principle
  • Result interpretation and analysis
  • Software tools for data processing and reporting

 

3. Troubleshooting Common Issues

  • Identifying and resolving common problems (e.g., baseline noise, cleanliness of cell)
  • Strategies for maintaining instrument performance
  • Preventive maintenance tips
  1. Adherence to Safety Protocols: Strictly follow all laboratory safety guidelines and protocols to prevent accidents and ensure the well-being of all participants.
  2. Active Participation: Engage actively in all training sessions, discussions, and practical exercises. Complete all assigned tasks and projects on time.
  3. Respect for Equipment and Facilities: Handle all laboratory equipment and materials with care. Report any damages or malfunctions to the instructor immediately.
  4. Collaboration and Teamwork: Work collaboratively with fellow participants, sharing knowledge and supporting each other’s learning.
  5. Integrity and Accuracy: Maintain a high standard of integrity in all testing procedures and documentation. Ensure that all results are accurate and reliable.

Commitment to the Program: Participants must demonstrate a commitment to the training program by attending all scheduled sessions, completing all assignments, and actively participating in practical exercises. A signed commitment agreement may be required before the start of the program.

Health and Safety Compliance: Participants must comply with health and safety regulations, including wearing appropriate personal protective equipment (PPE) and adhering to all safety protocols. A medical clearance or proof of immunizations may be required for certain training programs.

Designation: Trainee in PSA/DSC/NMR Division
Section: Training
Qualification: Ph. D./ M. Tech./ M. Sc./ B. Tech./ B. Sc.
Fees: As Per Industry Standards
Experience: Freshers / Professionals
Employment Type: Short Term / Long Term
Location: Gurugram, Haryana.

Note:

Limited Spots Available! Don’t Miss This Opportunity to Advance Your Skills in Particle Size Analysis!

For any further inquiries or additional information, please reach out.

We look forward to supporting your journey in Particle Size Analysis in various Industries.

CONTACT US FOR SERVICES
Please enable JavaScript in your browser to complete this form.

Get in Touch for Our Services

Please enable JavaScript in your browser to complete this form.